Product description
Sensirion SCD43 is a high-accuracy sensor for measuring carbon dioxide (CO2), temperature, and relative humidity. The sensor uses photoacoustic NDIR (Non-Dispersive Infrared) technology to directly measure CO2 concentration in the air. It is designed for applications such as indoor air quality monitoring, ventilation control, and air quality measurement.
The SCD43 is part of Sensirion's SCD4x series and offers higher measurement accuracy than the SCD40 and SCD41. The sensor combines Sensirion's PASens and CMOSens technologies with an integrated temperature and humidity sensor. CO2 measurement has a specified range of 400–5000 ppm with an accuracy of ±(30 ppm + 3% of reading).
The sensor features a digital I2C interface and supports continuous measurement with updates every 5 seconds, a low-power mode with updates every 30 seconds, and individual on-demand measurements (single-shot). The latter mode also makes the sensor suitable for battery-powered applications where low average power consumption is desired.
The SCD43 features automatic self-calibration (ASC) to maintain measurement accuracy over time. This function relies on the sensor being regularly exposed to air with a known minimum CO2 concentration. Forced recalibration (FRC) using an external reference value is also supported. The sensor also provides functions for compensating for ambient pressure and installation altitude.
The sensor is supplied as a compact surface-mount component with LGA connections and is designed for PCB assembly using reflow soldering.
Specifications:
- Manufacturer: Sensirion
- Model: SCD43-D-R2
- Sensor type: CO2, temperature, and relative humidity
- CO2 measurement principle: Photoacoustic NDIR (PASens)
- CO2 measurement range (specified): 400–5000 ppm
- CO2 output range: 0–40000 ppm
- CO2 accuracy: ±(30 ppm + 3% of reading)
- CO2 repeatability: ±10 ppm (typical)
- CO2 response time: 60 s (τ63%, typical)
- Temperature measurement range: -10 to +60 °C
- Temperature accuracy: ±0.8 °C at 15–35 °C (typical)
- Humidity measurement range: 0–100% RH
- Humidity accuracy: ±6% RH at 15–35 °C and 20–65% RH (typical)
- Supply voltage: 2.4–5.5 V DC
- Current consumption at 3.3 V: 15 mA (typical, continuous measurement)
- Current consumption in low-power mode at 3.3 V: 3.2 mA (typical)
- Current consumption in single-shot mode at 3.3 V: 0.45 mA (typical, one measurement every 5 minutes)
- Peak current at 3.3 V: 205 mA (max)
- Measurement interval: 5 s (normal), 30 s (low-power mode)
- Interface: I2C
- I2C address: 0x62
- I2C clock frequency: Up to 400 kHz
- Calibration: Automatic self-calibration (ASC) and forced recalibration (FRC)
- Operating temperature: -10 to +60 °C
- Operating humidity: 0–95% RH (non-condensing)
- Mounting: Surface mount (LGA), reflow soldering
- Dimensions: 10.1 x 10.1 x 6.5 mm
- Weight: Approx. 0.6 g
- Expected lifetime: Over 10 years (typical operating conditions)
- Compliance: RoHS, REACH