Description
Specifications
DC voltage: 0-200 mV / 2000 mV / 20 V / 200 V / 500 V
basic accuracy: ± (1.0% rdg + 2 digits) , ±(1.2% rdg + 2 digits) for 500 V range
input impedance: 1 MOhm
maximum input: 500 V
overload protection: 500 V DC or AC rms
AC voltage: 0-200 V / 500 V
basic accuracy: ± (1.5% rdg + 3 digits)
input impedance: 450 kOhm
frequency range: 40-500 Hz
maximum input: 500V RMS
DC current: 200 µA / 2000 µA / 20 mA / 200 mA / 10 A
basic accuracy: ± (1.5% rdg + 2 digits), ± (2.0% rdg + 2 digits) for 200mA range; ± (2.0% rdg + 3 digits) for 10 A range
overload protection: 0.5 A / 600 V fuse in mA range; 10 A / 600 V fuse in 10 A range
resistance: 0-200 Ohm / 2000 Ohm / 20k Ohm / 200 kOhm /2000 kOhm
basic accuracy: ± ( 1.0% rdg +3 digits); ± (1.0% rdg + 5 digits) for 200Ohm range, ± (1.5% rdg + 3 digits) for 2kOhm range
overload protection: 0.5 A / 600 V fuse
audible continuity measurement: built-in buzzer sounds if resistance is less than 50 Ohm
test voltage: approx. 1.8 V
diode measurement: test forward voltage of diode
test voltage: approx. 1.8 V
overrange: yes
continuity buzzer: yes
diode test: yes
low-battery indication: yes
maximum display: 3 ½
LCD display:
size: 47 x 15 mm
digits: max. 1999
ranging mode: manual
data hold: no
backlight: no
dimensions: 118 x 65 x 30 mm
weight (with battery): 100 g
power supply: 2 x 1.5 V AAA R03P (incl.)
auto power-off: no
operating environment:
temperature: 0 °C to 40 °C (32 to 104 °F)
humidity: < 80% RH.
storage environment:
temperature: -20 °C to 60 °C (-4 to 140 °F)
humidity: < 90% RH
fuse:
F0.5 A / 600 V 5 x 20 mm (not replaceable)
F10A / 600 V 5 x 20 mm (not replaceable)
test lead probe : CAT II 500 V / CAT III 300 V, 10 A, L = 90 cm